HWg Damocles2 1208 Set

$461.00

SKU: 600656 Categories: , ,

Damocles2 1208 provides 12 digital inputs and 8 digital outputs over the Ethernet and a secure Web interface. Secure communication supports connection to SNMP v3, SCADA systems and MQTT portals for IoT. Pulse counters on digital inputs. Recommended starter pack containing Damocles2 1208, power adaptor and HWg CD with user manual.

Damocles2 1208 is an Ethernet I/O unit with enhanced security and an excellent cost per I/O pin ratio. Inputs and outputs can be controlled over the secure Web interface or various M2M protocols. Digital inputs can be used to connect up to 12 dry contacts (e.g. door contacts) or S0 pulse outputs (e.g. electricity meter). Digital outputs (open collector) can be used to control relays, or for example switch 110/230V sockets (via PowerEgg2). Damocles2 1208 fits on a DIN rail. Outputs are OC (Open Collector), can control external relays but are not electrically isolated.

  • Email and SMS alerts
    When the state (open/closed) of a contact connected to a digital input changes, Damocles2 can send an e-mail to a maximum of 5 recipients (or a SNMP Trap / SMS alert).

    Dry contact alarm can be delayed (for example to send an alert if a cooler door stays open for more than 5 minutes). Damocles2 can send e-mail using the secure TLS protocol.

    All HW group devices can send text messages (SMS) through a single central gateway, the HWg-SMS-GW. Just a single SIM card can serve all your devices.

  • Remote digital outputs (Box-2-Box mode)
    Digital outputs (DO) of Damocles2 1208 can be controlled over a LAN from other HW group products. We call this the “Box-2-Box” mode. For example, alarms from several Poseidon2 units or water leak detectors can be signaled at a single location with a single Damocles2 1208 unit.
  • Secure signaling of I/O states over a LAN
    Damocles2 supports secure protocols for M2M communication with central software: SNMP v3, MQTT for cloud (IoT) applications, XML over HTTPs, TLS for sending e-mail.
  • Applications
    A typical application of Damocles2 1208 is secure connection of remote DI (digital inputs) and DO (digital outputs) to a software. Customers use it to monitor doors in a building, security system status, or various detectors. It can be connected to over 50 different third-party SNMP or SCADA applications.

    Some customers use Damocles2 and its S0 counter function in smart homes to monitor the technology and for water or electricity consumption billing (with a S0 energy meter).

    • Server room environment monitoring
      • Temperature in a 19″ cabinet and in the room
      • Remote environment monitoring (lights, power, fire protection system, …)
      • IT monitoring of security systems (alarms, room / cabinet doors monitoring, …)
    • Remote environmental monitoring in a cabinet or in a datacenter
      • Temperature and humidity in the datacenter (inside racks, in the A/C outlet, under the raised floor)
      • Detection of redundant power failures
      • SNMP environment monitoring system
    • Air-conditioning monitoring
      • A/C, temperature, humidity monitoring
      • Control of additional cooling in a room or in a rack
      • Alert to leaking water
    • UPS / back-up generator monitoring
      Fuel level, diesel generator status, remote start over IP, monitoring of temperature and service contacts
    • Remote I/O control and monitoring over the Ethernet
      Monitors a remote environment, sensor values can be fed into any SNMP system. Enables remote reading of dry contact inputs and remote control of relay outputs (to turn on HVAC, restart a server, start a diesel generator, …).
    • Industrial applications
      Remote monitoring of dry contacts, 4-20mA sensors or Pt-100 and Pt-1000 temperature probes.
      Data logger stores the values in the internal memory. Modbus/TCP protocol can be used for integration with SCADA systems.
    • Cooler and freezer monitoring alarm indication
      Measures temperature and humidity in a cooler or a freezer. When a value is out of a safe range, a relay output is activated to e.g. turn on a warning light or sound a horn. Suitable for monitoring storages of food or pharmaceuticals. We recommend the PDMS software to monitor temperature.
    • Temperature and other measurements in a cloud
      Poseidon2 remote monitoring device can be connected to cloud systems. Contact us for details.
    • Surveillance systems
      Sensor readings and detector states can be fed to IP camera systems of various brands. Digital Outputs can be used to turn on the lights in a certain zone or open/close gates.
    • Smart buildings
      Sensor readings can be shared in several applications. Relay outputs can be controlled as remote I/O.

    Live demo: http://damocles-2404.hwg.cz/general.xml//TruePath is the exclusive partner of HWgroup covering their entire product line.  Feel free to contact us for direct sales, distributor sales and technical support.